top of page
Home: Image
several diagrams cropped.jpg

Control Panels for the Radiant Heat Industry

Heating Driveways, Heated Asphalt Driveway, Tempurtech Heated roof, WarmZone, Warm Zone Radiant Heat, Heated Sidewalks, Radiant Heat

Driveways Heated, Electric Heated Driveway, Danfoss Heated Driveway, Watts Heated Driveway, Snow Sensor, Ice Sensor, Heated Walkway

New Heated Driveway, New Radiant Heated Driveway, Electric Heated Asphalt Driveway, Heated Paver Driveway, Heated Sidewalk, Heated Roof

Colorado, Nevada, New York, Vermont, Washington State, Maine, Pennsylvania, New Jersey, Maryland, Michigan, Rhode Island, Montana, Idaho

Wisconsin, Dakota, Nebraska, Ohio, Maine, Utah, Indiana, Connecticut, Massachusetts, Michigan, Minnesota,  Oregon,

Designed and Built "Ready for Power"

Welcome to Snow Controller.com

 

Using our proven and NEC, BOCA, IECC, NFPA Code compliant "Ready for Power" control station will save you time and money.

​

We provided complete control station design and build services.

​

  • UPSCALE RESIDENTIAL   

  • COMMERCIAL  

  • INDUSTRIAL

Control stations for any radiant heating needs.

​

We can ship from stock within 3-5 business days

or

We can design, build and ship within 3 weeks a control station meeting your projects custom control station needs.

​

      COMPLETELY PRE-WIRED

 Field hook-up is as simple as 1  2  3

 

(1)

THE CONTROL STATION

Bring single phase or three phase power to the control station sub panel

(available in) 1-Phase 208 volt, 240 volt and 3-Phase 208 volt, 240 volt, 460 volt.

 

(2)

THE SENSOR

Wire the sensor to the control station.

Field hook-up is very simple. 

Connect the available color coordinated wiring harness from the sensor to the trough. 

Wiring Harness is a THHN/THWN 5 wire and is color coded end to end.

​

3

RADIANT MAT WIRING

Your control station will contain an electrical trough. 

All radiant cold lead connections will be terminated in the trough and will be pre-marked.

EXAMPLE: - Your order was for a two zone system including 12 radiant mats, 6 mats for zone 1 and 6 mats for zone 2. 

All the field electrician needs to do is run the Zone 1, Mat "A" (marked as Zone-1-Mat-"A") into the control station trough.

Then connect the Zone 1 Mat "A" to the two wires marked Zone-1-Mat-"A" and so on.  

That's it.

​

Once the main power feed is run to the sub panel,

Once the the sensor wire is run into the trough,

Once the radiant mats cold leads are run into the trough,

The total on site field connection time is then less than 3 hours for one technician.

​

SAVINGS

Once all your outdoor radiant materials are delivered you would  then first need to figure out:

​

1- What size control panels to order

2- How many control panels with how many magnetic contactors in each

3- The total amperage size of the panels 100 max, 200 max allowed

4- Will there be a pre-heat over ride and if so how long

5- Matching the control / sensor and coil control voltages

6- What size sub panel to order / due to not just load but spaces required.

7- Type of panel will it be bolt on or push on

8- What type of sub panel main lug or main breaker

9- What sizes magnetic contactors for each radiant zone mat or cable

10- How many zones per controller will fit

11- Field familiarize on how to wire the control side contactor coils, pre-heat timers

12- does the system require 30ma-GFEP lockout per the NEC

13- Will there be visual system on indicators

14- Due to amperage constraints will there need to be a NEC required 2nd zone mechanical lockout

15- If second zone lock out is required where will it wire to and where will it mount

16- Field familiarize on the line side piping & wiring

17- Field familiarize on the load side piping and wiring

18- First figure out a basic materials list

19- Order your materials from various suppliers and manufacturers

20- Check codes on GFEP where required where will GFEP mount and where will GFEP panel sensor mount

21- Figure out best placement for coil transient spike arrester for coil and sensor circuit per manufacturer

22-First start the in field layout process

23- Drive pick up all materials

24- Deliver to field site / job box / tables, lights, charging station

25- Assembly then first begins

​

The time for the above listed #1 - #24 plus the actual field build depending on size can easily turn into a week or more.

Not to mention the issues of diagnosis of any system issues due to unfamiliarity to this type of system

We cut all that out for you.

 

For an in the field walk through, design, order, deliver, set up, build and test out / shakedown

for two electricians or an electrician and a journeyman not to mention the actual cost of purchasing

all the materials is much more than simply ordering what you need and having it delivered.

 

Install a "Ready for Power" control station.

​

Unscrew the control station from the delivery pallet and mount it to the wall.

Run your primary power leads

Run your outdoor sensor leads

Run your radiant heater leads

​​

Over-Built to last with the warranties to prove it. 

Warranties depending on order up to 10 years.

​

ORDERING IS MADE SIMPLE

Provide us your layout

Provide us the radiant manufacturer.

​Provide us with how many zones

Provide us how many radiant mats for each zone

Provide us amperage for each radiant mat.

Provide us your site voltage,

Provide us you site phase

​

If you are unsure of the above or do not have a site layout email us or call us.

We will schedule a phone consultation to figure out your design with you.

​

​

AVAILABLE OPTIONS

Pre-Installed and wired including any GFEP protection if required.

​

Pre-Installed down line, INLINE fusing for the sensors.

​

Pre-installed OEM panel and equipment surge protection

​

Pre-greased fittings using a NO-OX compound

​

Pre-Installed 4 zone WIFI SnowController Spring / Summer 2020

​

Pre-Installed 120 volt convenience outlet.

​

5 wire THWN Sensor wiring harness, just tell us how much you need,

25' 50' 100' 200' 300' 400' 500'

​

Magnetic Control Contactors upgrade from 20 amp to 30, 40 up to 50 amp.

​

Control Voltage side Anti-Spike Coil Protection.  Prevent Contactor arc from shutting down the system sensor.

​

Pre-Installed and wired manual large storm event preheat timer, 4 hour, 6 hour.

​

System Red or Green LED on visual indicator light for each zone.

​

Pre-Wired and Pre-Marked Generator lock out connection. 

Lock out the system or a zone when the on-site generator is in use.

​

Upgrade to a trough with knock outs for ease of wiring.

​

Advise us if power will be routed through the trough. 

You tell us where and we will pre-punch your incoming power KO for you. - 

Up to 4", a true field time saver.
 

Home: Welcome
Home: Gallery

Call us for a custom quote or to discuss your projects needs

Heating Driveways, Heated Asphalt Driveway, Tempurtech Heated roof, WarmZone, Warm Zone Radiant Heat, Heated Sidewalks, Radiant Heat

Driveways Heated, Electric Heated Driveway, Danfoss Heated Driveway, Watts Heated Driveway, Snow Sensor, Ice Sensor, Heated Walkway

New Heated Driveway, New Radiant Heated Driveway, Electric Heated Asphalt Driveway, Heated Paver Driveway, Heated Sidewalk, Heated Roof

Colorado, Nevada, New York, Vermont, Washington State, Maine, Pennsylvania, New Jersey, Maryland, Michigan, Rhode Island, Montana, Idaho

Wisconsin, Dakota, Nebraska, Ohio, Maine, Utah, Indiana, Connecticut, Massachusetts, Michigan, Minnesota,  Oregon,

Standard Control Station Packages

1-PH 60 Amp   8 Circuit Only
Single Zone Control Station

INCLUDES THE FOLLOWING
1- 60 Amp Sub Panel 1-ph.
1- 4" X 4"X 36" Electrical Trough (No-KOs)
Up to 3 Individual Radiant Mats 40 Amp Max
1 Control Circuit 120 Volt Pre-Wired
8x Breakers, 6X 2-Pole-Radiant,
1-SP Controls 1-SP Sensor
Complete Wiring Integration
Continuous Grounding Throughout
Easy to View Labeling Throughout
All Required Breakers Installed
80 Amp Main Breaker Included
All Panels, Breakers, Controls Pre-Wired
$3350.00 - Other Options Available

1-PH 80 Amp   10 Circuit Only
Single Zone Control Station

INCLUDES THE FOLLOWING
1- 80 Amp Sub Panel 1-ph.
1- 4" X 4"X 36" Electrical Trough (No-KOs)
Up to 4 Individual Radiant Mats
60 Amp max @240 volt Max
1 Control Circuit 120 Volt Pre-Wired
10x Breakers, 4x 2-Pole Radiant, 1-SP Control and 1-SP Sensor
Complete Wiring Integration
Continuous Grounding Throughout
Easy to View Labeling Throughout
All Required Breakers Installed
80 Amp Main Breaker Installed
All Panels, Breakers, Controls Pre-Wired
$3450.00 - Other Options Available

1-PH 100 Amp   10 Circuit Only
Single Zone Control Station

INCLUDES THE FOLLOWING
1- 100 Amp Sub Panel 1-PH.
1- 4" X 4"X 36" Electrical Trough (No-KOs)
Up to 4 Individual Radiant Mats
80 Amp @ 240 volt Max
1 Control Circuit 120 Volt Pre-Wired
10x Breakers, 4x 2-Pole Radiant,
1-SP Control 1-SP Sensor
Complete Wiring Integration
Continuous Grounding Throughout
Easy to View Labeling Throughout
All Required Breakers Installed
100 Amp Main Breaker Installed
All Panels, Breakers, Controls Pre-Wired
$3650.00 - Other Options Available

1-PH 125 Amp   14 Circuit Only
Single Zone Control Station

INCLUDES THE FOLLOWING
1- 125 Amp Sub Panel 1-PH.
1- 6" X 6"X 36" Electrical Trough (No-KOs)
Up to 6 Individual Radiant Circuits
90 Amp Max Draw
1 Control Circuit 120 Volt Pre-Wired
14x Breakers 6x 2-Pole-Radiant
1x SP-Control 1x SP--Sensor
Complete Wiring Integration
Continuous Grounding Throughout
Easy to View Labeling Throughout
All Required Breakers Installed & Wired
125 Amp Main Breaker Installed
All Panels, Breakers, Controls Pre-Wired
$3950.00 - Other Options Available

1-PH 125 Amp    18 Circuit Only
Single Zone Control Station

INCLUDES THE FOLLOWING
1- 125 Amp Sub Panel 1-PH.
1- 6" X 6"X 36" Electrical Trough (No-KOs)
Up to 8 Individual Radiant Circuits
100 Amp Max Draw
1 Control Circuit 120 Volt Pre-Wired
10x Breakers 8x 2-Pole-Radiant
1-SP Control 1-SP Sensor
Complete Wiring Integration
Continuous Grounding Throughout
Easy to View Labeling Throughout
All Required Breakers Installed & Wired
125 Amp Main Breaker Installed
All Panels, Breakers, Controls Pre-Wired
$4150.00 - Other Options Available

1-Ph 200 Amp 22 Circuit Only
Single Zone Control Station

INCLUDES THE FOLLOWING
1- 200 Amp Sub Panel 1-PH.
1- 6" X 6"X 36" Electrical Trough (No-KOs)
Up to 10 Individual Radiant Circuits 
100 amp Max Draw
1 Control Circuit 120 Volt Pre-Wired
12x Breakers  10x-2Pole Radiant     1-Control 1-Sensor
Complete Wiring Integration
Continuous Grounding Throughout
Easy to View Labeling Throughout
All Required Breakers Installed & Wired
125 Amp Main Breaker Installed
All Panels, Breakers, Controls Pre-Wired
$4250.00 - Other Options Available

Home: List

1PH 200 Amp    24 Circuit Only

INCLUDES THE FOLLOWING
1- 200 Amp Sub Panel 1-PH.
1- 6" X 6"X 36" Electrical Trough (No-KOs)
Up to 12 Individual Radiant Circuits 
100 amp Max Draw
1 Control Circuit 120 Volt Pre-Wired
13x Breakers  11x-2Pole Radiant
1-SP Controls 1-SP Sensor
Complete Wiring Integration
Continuous Grounding Throughout
Easy to View Labeling Throughout
All Required Breakers Installed & Wired
125 Amp Main Breaker Installed
All Panels, Breakers, Controls Pre-Wired
$4550.00 - Other Options Available

1PH 100 Amp     2-ZONE 6 Circuit

INCLUDES THE FOLLOWING
1- 100 Amp Sub Panel 1-PH.
1- 6" X 6 "X 48" Electrical Trough (No-KOs)
Up to 6 Individual Radiant Circuits 
60 amp Max Draw
1 Control Circuit 120 Volt Pre-Wired
5x Breakers  3x-2Pole Radiant
1-Control 1-Sensor
Complete Wiring Integration
Wired for 1 zone automatic sensor
Wired for 1 zone manual-with lockout
Continuous Grounding Throughout
Easy to View Labeling Throughout
All Required Breakers Installed & Wired
125 Amp Main Breaker Installed
All Panels, Breakers, Controls Pre-Wired
$4750.00 - Other Options Available

1PH 100     Amp 2-Zone 10 Circuit

INCLUDES THE FOLLOWING
1- 100 Amp Sub Panel 1-PH.
1- 6" X 6 "X 48" Electrical Trough (No-KOs)
Up to 8 Individual Radiant Circuits 
75 amp Max Draw
1 Control Circuit 120 Volt Pre-Wired
7x Breakers  5x-2Pole Radiant
1-Control 1-Sensor
Complete Wiring Integration
Wired for 1 zone automatic sensor
Wired for 1 zone manual-with lockout
Continuous Grounding Throughout
Easy to View Labeling Throughout
All Required Breakers Installed & Wired
125 Amp Main Breaker Installed
All Panels, Breakers, Controls Pre-Wired
$4950.00 - Other Options Available

125 Amp   2-Zone 12 Circuit

INCLUDES THE FOLLOWING
1- 125 Amp Sub Panel 1-PH.
1- 6" X 6 "X 48" Electrical Trough (No-KOs)
Up to 8 Individual Radiant Circuits 
100 amp Max Draw
1 Control Circuit 120 Volt Pre-Wired
7x Breakers  5x-2Pole Radiant
1-SP Control 1-SP Sensor
Complete Wiring Integration
Wired for 1 zone automatic sensor
Wired for 1 zone manual-with lockout
Continuous Grounding Throughout
Easy to View Labeling Throughout
All Required Breakers Installed & Wired
125 Amp Main Breaker Installed
All Panels, Breakers, Controls Pre-Wired
$5050.00 - Other Options Available

200 Amp    2-Zone 22 Circuit

INCLUDES THE FOLLOWING
1- 200 Amp ML Sub Panel 1-PH.
1- 6" X 6 "X 48" Electrical Trough (No-KOs)
Up to 8 Individual Radiant Circuits 
100 amp Max Draw
1 Control Circuit 120 Volt Pre-Wired
11x Breakers  10x-2Pole Radiant
1-SP Control 1-SP Sensor
Complete Wiring Integration
Wired for 1 zone automatic sensor
Wired for 1 zone manual-with lockout
Continuous Grounding Throughout
Easy to View Labeling Throughout
All Required Breakers Installed & Wired
Mounted on black painted PT 7/8 Ply
All Panels, Breakers, Controls Pre-Wired
$5350.00 - Other Options Available

200 AMP 2-Zone - 2- Sensor

INCLUDES THE FOLLOWING
1- 200 Amp ML Sub Panel 1-PH.
1- 6" X 6 "X 48" Electrical Trough (No-KOs)
Up to 12 Individual Radiant Circuits 
150 amp Max Draw
2 Control Circuit 120 Volt Pre-Wired
16x Breakers  12x-2Pole Radiant
2-SP Control 2-SP Sensor
Complete Wiring Integration
Wired for 1 zone automatic sensor
Wired for 2nd zone automatic
Continuous Grounding Throughout
Easy to View Labeling Throughout
All Required Breakers Installed & Wired
Mounted on black painted PT 7/8 Ply
All Panels, Breakers, Controls Pre-Wired
$5550.00 - Other Options Available

Home: List
contactor line drawing.jpg

Discounts for TEMPURTECH Clients

Tempurtech Purchasers:

Packages purchased for TEMPURTECH systems have many of the options below already added into their control station design.

 

TEMPURTECH matched control stations will already have the upgrade options, providing the years of in service longevity you expect.

​

Example:

1- NO-OX included

2- LED indicators Included

3- 30 amp contactor upgrade Included

4- 4 Hour Pre-Heat timers Included

​

Above #1 - #4 Normal Cost $700.00.

We Include the above free of charge

for Tempurtech clients.

​​

Please Inquire.

Home: Quote

Options

Options can be added to any Control Station

Add optional zone to a control panel

Addition of 2 pole breaker, 2 Pole wiring to Controller, Wiring to control 120 volt coil
Approximate Cost $225.00

Grease All connections with NO-OX

Cover all copper to non copper connections with NO-OX helps prevent oxidation and seizing of wire bonds to contactors, breakers, lugs, neutrals, grounds.
Single Zone $50.00
Two Zone  $75.00

Surge Suppression

Single Zone 100 Amp Panel $325.00
Single Zone 125 Amp Panel $375.00
Single Zone 200 Amp Panel $400.00
Any Two Zone Station $500.00
5 Year Warranty against Defects
Suppression against high voltage Spikes
Suppression against transient Spikes

FUTURE WIFI

Pre Pipe and wire control system for WIFI
INCLUDES
Piping for control wiring
Wiring pre marked
Outlet for 120 volt to plug WIFI into
$225.00

Control Contact Amperage Type

Upgrade included 20 amp contactors
Upgrade ALL 20 amp contactors to
30 amp $65 ea.
Upgrade 20 amp contactors to
40 amp $100 ea
40 amp upgrade includes upgrade from a 1 year warranty to 5 years on controllers.

Manual Pre-Heat

Upgrade system to 4 hour

pre-heat timers $125 per panel

​

Upgrade system to 6 hour

pre heat-timers $160.00 per panel

Home: Skills

VISUAL INDICATORS

LED Indicators RED or Green
Know at a glance if the system is active
$55.00 any panel

SENSOR PROTECTION

Transient spike suppression
After the sub panel each time the control contactors open or close the is an energy arc/spike/RF signal.  This has been

known to shut down sensor

circuits due to false  triggers
Inline coil/sensor/arc suppression $125 ea.

TROUGH ENTRANCE

Upgrade to a Trough with pre pressed KO's on the top and the bottom of the trough.   Small upgrade provides  in field ease for wiring, no drilling.  1/2", 3/4" and 1" included.
$50.00

POWER ENTRANCE KO

If you know where your entrance power is coming in we can pre punch the solid trough to your entrance size up to 4"
POR

WIRING HARNESS
FOR SENSOR

Color coded so there is ZERO mix up

​

$2.00 per foot up to 100'

$2.50 per foot from 101' to 250'

$3.00 per foot from 251' to 500'

FUSING SENSOR CIRCUIT

IN-LINE fusing of the sensor circuit.
The sensor circuit control side draws less than 1 amp, when wired to your
standard 15 amp SP breaker.
This provides little in the way of control circuit protection especially on longer runs.
Provide additional in-line protection $40.00 per sensor.

Home: Skills

​

Coming Spring 2020

WIFI Control Your Radiant System

4 Zone WIFI Control with APP

Phone Control From Anywhere

THE  MOST VERSATILE, INSTALLER AND END USER FRIENDLY

4 ZONE PHONE WIFI CONTROL SYSTEM & APP

​

  • Available in single zone and up to four zones

  • Transient spike protection on inlet power

  • Set it and forget it - Set your system to come on up to 24 hours in advance

  • Bypass it and forget it

  • Be Green, Set your system to stay off due to wind blowing flurries around for up to 48 hours

  • Omni direction antenna 2.4ghz

  • Tamper protection and notification to end user that someone is accessing the control system

  • Use log for up to the last 50 events/uses.  Upon Request.  See when the system was last used

  • 10 Year warranty

  • IP69 Gasketed cover

​

​

Home: About
Home: Work

Buy an edge. 

Use our knowledge.

Save time and money.

Most importantly get it right.

​

35 years and counting of electrical and control work gives us an edge.

 Upscale Residentail - Commercial - Industrial

Designed and Built

to save you time and money.

​

​We know what works

and what does not.

​

Purchase a Ready for Power

Control Station today.

​

Home: About
125 2 ZONE 20 ZONE WITH GFEP PRE INSTALLED _edited.jpg

All Panels Use UL rated components.
Ready for Inspection Right out of the box...  Well, right off the pallet..

Designed to save you money and time

ORDER YOUR CONTROL PACKAGE TODAY

Home: Bio
Home: Work
Home: Quote
hand drawn.jpg

Email or Call today we will provide you a link to our order form or we can do a phone order once we find out some project particulars.

Address:

3 Forrester Avenue, Suite 19 Warwick New York 10990

Email:

Phone:

Call Us To Order or for Questions on Designs  1-973-728-5745

Heating Driveways  Heated Asphalt Driveway  Tempurtech Heated Roof  WarmZone  Warm Zone Radiant Heat  Heated Sidewalks Radiant Heat

Driveways Heated  Electric Heated Driveway Danfoss Heated Driveway Watts Heated Driveway  Snow Sensor  Ice Sensor  Heated Walkway

New Heated Driveway  New Radiant Heated Driveway Electric Heated Asphalt Driveway Heated Paver Driveway Heated Sidewalk  Heated Roof

Colorado Nevada New York Vermont Washington State Maine Pennsylvania New Jersey Maryland Michigan Rhode Island Montana Idaho

Wisconsin Dakota Nebraska Ohio Maine Utah Indiana Connecticut Massachusetts Michigan Minnesota Oregon Tarrytown NY

Summit NJ Montville NJ West Orange NJ Saddle River NJ Upper Saddle River NJ Alpine NJ Westchester NY Long Island NY

Paramus NJ Mahwah NJ Summit NJ Florham Park NJ

​

Home: Contact

©2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019,2020, 2021, 2022, 2023 by Snow Controller.com - No pictures, information, or quotes may be copied, removed, used without written permission from this website's owner.  - We won't just chase you, we will catch you and sue you for real money.  Be nice, just ask.
We use WIX websites, its so cool.

Heating Driveways, Heated Asphalt Driveway, Tempurtech Heated roof, WarmZone, Warm Zone Radiant Heat, Heated Sidewalks, Radiant Heat

Driveways Heated, Electric Heated Driveway, Danfoss Heated Driveway, Watts Heated Driveway, Snow Sensor, Ice Sensor, Heated Walkway

New Heated Driveway, New Radiant Heated Driveway, Electric Heated Asphalt Driveway, Heated Paver Driveway, Heated Sidewalk, Heated Roof

Colorado, Nevada, New York, Vermont, Washington State, Maine, Pennsylvania, New Jersey, Maryland, Michigan, Rhode Island, Montana, Idaho

Wisconsin, Dakota, Nebraska, Ohio, Maine, Utah, Indiana, Connecticut, Massachusetts, Michigan, Minnesota,  Oregon,

bottom of page